Allied Engineering Corporation

Example
Analysis examples of ADVENTURECluster.
Steady heat conduction analysis
Steady heat conduction analysis is performed on the following two models using ADVENTURECluster and MSC.Nastran, and the results are compared.

The heat conductivity is 1.0W/m degC. As to the boundary condition, the room temperature 100degC and the heat transfercofficient 0.0002W/m2degC are assumed on the surface indicated by arrows, and the room temperature 20degC and the heat transfercofficient 0.0001W/m2degC are assumed on the other surfaces. All the elements are the quadratic tetrahedral.

Model 1Model 2

Fig. 1 Analysis model
The analysis results are as follows. Almost the same results are obtained from MSC.Nastran and ADVENTURECluster.

NastranADVENTURECluster

Fig. 2 Result of Model 1

NastranADVENTURECluster

Fig.3 Result of Model 2

Contact Us
Contact us at:
postmaster@alde.co.jp

if you have any questions.

ANALYSIS EXAMPLES

(C) 2001-2012 Allied Engineering Corporation. All rights reserved.